Solar plant: site data
Solar power plant in Verbivka, Chortkivskyi Raion, Ternopil Oblast
Verbivka: 1,115 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 2.1% above the oblast median (1,093). #160 of 296 in the rayon, #160 of 744 in the oblast.
Chortkiv, the rayon centre, is 43 km away. 181 m above sea level. 27 km away: Kamyanets-Podilskyi, the nearest bigger centre, 1,129 — 1.2% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 56 km. 10.76 m between rows, pitch 14.63 m (latitude 48.8°).
- Yield of 1 kWp
- 1,115kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 11,154kWh/year
- Row pitch
- 14.63m · GCR 0.33
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,320 / 500Pa
Ground frame designer
A ground frame for a solar plant: Verbivka
The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 56 km: snow 1,320 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 141 kWh/kWp, December: 32 — 4.4 times less.
January: 37 against 34 in the oblast, 8.8% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,577 | 705 | 160 |
| 10 | 11,154 | 1,410 | 320 |
| 15 | 16,731 | 2,115 | 480 |
Example: a 10 kW ground frame
For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.
How these numbers are computed
Nearby
- Pidpylypia1 km1,115 kWh/kWp
- Podolyany1 km1,114 kWh/kWp
- Zaluchchia2 km1,127 kWh/kWp
- Pukliaky3 km1,114 kWh/kWp
- Turylche3 km1,116 kWh/kWp
- Nyvra5 km1,127 kWh/kWp
All places: Chortkivskyi RaionTernopil Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.