Solar plant: site data

Solar power plant in Rekshyn, Ternopilskyi Raion, Ternopil Oblast

Rekshyn: 1,092 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). Exactly the oblast median (1,093). #90 of 313 in the rayon, #382 of 744 in the oblast.

Ternopil, the rayon centre, is 54 km away. 297 m above sea level. 15 km away: Berezhany, the nearest bigger centre, the same 1,094. Snow and wind from the nearest regional centre in the DBN — Тернопіль, 54 km. 11.96 m between rows, pitch 15.73 m (latitude 49.6°).

Yield of 1 kWp
1,092kWh/year
Tilt
38°2° east of south
10 kW
10,922kWh/year
Row pitch
15.73m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,390 / 520Pa

Ground frame designer

A ground frame for a solar plant: Rekshyn

The designer opens with this place’s coordinates, latitude 49.6° for the row spacing and the DBN loads of the nearest regional centre — Тернопіль, 54 km: snow 1,390 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan57Feb94Mar115Apr126May128Jun135Jul132Aug108Sep84Oct41Nov33Dec

July: 135 kWh/kWp, December: 33 — 4.1 times less.

January: 40 against 34 in the oblast, 17.6% more.

Rekshyn: plants, kWh
kWpA yearJulyDecember
55,461675165
1010,9221,350330
1516,3832,025495

Snow and wind: Тернопіль

Example: a 10 kW ground frame

For the loads of Ternopil: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Ternopilskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.