Solar plant: site data

Solar power plant in Leykiv, Myrhorodskyi Raion, Poltava Oblast

Leykiv: 1,132 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.8% below the oblast median (1,142). #217 of 430 in the rayon, #1400 of 1856 in the oblast.

Myrhorod, the rayon centre, is 23 km away. 94 m above sea level. 7 km away: Shyshaky, the nearest bigger centre, the same 1,133. Snow and wind from the nearest regional centre in the DBN — Полтава, 57 km. 12.00 m between rows, pitch 15.82 m (latitude 49.9°).

Yield of 1 kWp
1,132kWh/year
Tilt
37°2° east of south
10 kW
11,324kWh/year
Row pitch
15.82m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,450 / 470Pa

Ground frame designer

A ground frame for a solar plant: Leykiv

The designer opens with this place’s coordinates, latitude 49.9° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 57 km: snow 1,450 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan58Feb96Mar117Apr138May140Jun144Jul143Aug114Sep81Oct38Nov26Dec

July: 144 kWh/kWp, December: 26 — 5.5 times less.

January: 39 against 35 in the oblast, 11.4% more.

Leykiv: plants, kWh
kWpA yearJulyDecember
55,662720130
1011,3241,440260
1516,9862,160390

Snow and wind: Полтава

Example: a 10 kW ground frame

For the loads of Poltava: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Myrhorodskyi RaionPoltava Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.