Poland: solar plant site data
Solar power plant in Jelenia Góra, Poland: yield, tilt angle and row spacing
Jelenia Góra: 1,058 kWh per kWp a year at the optimal tilt of 40°, 4° east of south (PVGIS). 0.7% below the median of the main cities of Poland (1,065). #59 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 5.1% less here.
Jelenia Góra is in Lower Silesian Voivodeship. Population 77,366 (GeoNames). 331 m above sea level. 42 km away: Wałbrzych, the nearest bigger city, 1,043 kWh/kWp — 1.4% more here. 13.87 m between rows, pitch 17.53 m, GCR 0.27 (latitude 50.9°).
- Yield of 1 kWp
- 1,058kWh/year
- Tilt
- 40°4° east of south
- 10 kW
- 10,576kWh/year
- Row pitch
- 17.53m · GCR 0.27
- Rank in the country
- 59of 87 cities
Ground frame designer
A ground frame for a solar plant: Jelenia Góra
Latitude 50.9°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 124 kWh/kWp, December: 39 — 3.2 times less.
November: 50 against the median of 41 for the main cities of Poland, 22.0% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,288 | 620 | 195 |
| 10 | 10,576 | 1,240 | 390 |
| 15 | 15,864 | 1,860 | 585 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.