Solar plant: site data

Solar power plant in Mykolaivka Persha, Podilskyi Raion, Odesa Oblast

Mykolaivka Persha: 1,186 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 2.9% below the oblast median (1,221). #93 of 301 in the rayon, #961 of 1177 in the oblast.

Balta, the rayon centre, is 18 km away. 238 m above sea level. 18 km away: Balta, the nearest bigger centre, 1,176 — 0.8% more here. Snow and wind from the nearest regional centre in the DBN — Одеса, 171 km. 10.06 m between rows, pitch 13.93 m (latitude 47.8°).

Yield of 1 kWp
1,186kWh/year
Tilt
36°2° east of south
10 kW
11,857kWh/year
Row pitch
13.93m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
880 / 460Pa

Ground frame designer

A ground frame for a solar plant: Mykolaivka Persha

The designer opens with this place’s coordinates, latitude 47.8° for the row spacing and the DBN loads of the nearest regional centre — Одеса, 171 km: snow 880 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan55Feb100Mar121Apr139May141Jun148Jul145Aug120Sep95Oct48Nov35Dec

July: 148 kWh/kWp, December: 35 — 4.2 times less.

December: 35 against 38 in the oblast, 7.9% less.

Mykolaivka Persha: plants, kWh
kWpA yearJulyDecember
55,929740175
1011,8571,480350
1517,7862,220525

Snow and wind: Одеса

Example: a 10 kW ground frame

For the loads of Odesa: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Podilskyi RaionOdesa Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.