Solar power plant in Ozerne, Mykolaivskyi Raion, Mykolaiv Oblast
Ozerne: 1,196 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). Exactly the oblast median (1,198). #234 of 238 in the rayon, #482 of 909 in the oblast.
Mykolayiv, the rayon centre, is 59 km away. 94 m above sea level. 25 km away: Nova Odesa, the nearest bigger centre, 1,212 — 1.4% less here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 60 km. 9.88 m between rows, pitch 13.75 m (latitude 47.5°).
- Yield of 1 kWp
- 1,196kWh/year
- Tilt
- 36°3° east of south
- 10 kW
- 11,958kWh/year
- Row pitch
- 13.75m · GCR 0.35
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 870 / 470Pa
Ground frame designer
A ground frame for a solar plant: Ozerne
The designer opens with this place’s coordinates, latitude 47.5° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 60 km: snow 870 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 154 kWh/kWp, December: 33 — 4.7 times less.
January: 36 against 38 in the oblast, 5.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,979 | 770 | 165 |
| 10 | 11,958 | 1,540 | 330 |
| 15 | 17,937 | 2,310 | 495 |
Example: a 10 kW ground frame
For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.
How these numbers are computed
Nearby
- Yasna Polyana3 km1,195 kWh/kWp
- Dymivske4 km1,198 kWh/kWp
- Hrebenyky5 km1,200 kWh/kWp
- Novooleksandrivské6 km1,197 kWh/kWp
- Novooleksandrivka6 km1,196 kWh/kWp
- Kyyivske6 km1,201 kWh/kWp
All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.