Solar plant: site data

Solar power plant in Oleksandrivka, Mykolaivskyi Raion, Mykolaiv Oblast

Oleksandrivka: 1,201 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). Exactly the oblast median (1,198). #229 of 238 in the rayon, #421 of 909 in the oblast.

Mykolayiv, the rayon centre, is 64 km away. 37 m above sea level. 30 km away: Bashtanka, the nearest bigger centre, the same 1,202. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 65 km. 9.90 m between rows, pitch 13.77 m (latitude 47.5°).

Yield of 1 kWp
1,201kWh/year
Tilt
36°3° east of south
10 kW
12,006kWh/year
Row pitch
13.77m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Oleksandrivka

The designer opens with this place’s coordinates, latitude 47.5° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 65 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan54Feb99Mar124Apr139May140Jun154Jul150Aug125Sep97Oct49Nov32Dec

July: 154 kWh/kWp, December: 32 — 4.8 times less.

December: 32 against 33 in the oblast, 3.0% less.

Oleksandrivka: plants, kWh
kWpA yearJulyDecember
56,003770160
1012,0061,540320
1518,0092,310480

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.