Solar plant: site data

Solar power plant in Nadbuzke, Mykolaivskyi Raion, Mykolaiv Oblast

Nadbuzke: 1,246 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 4.0% above the oblast median (1,198). #91 of 238 in the rayon, #94 of 909 in the oblast.

Mykolayiv, the rayon centre, is 10 km away. 45 m above sea level. 10 km away: Mykolayiv, the nearest bigger centre, 1,253 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 10 km. 9.78 m between rows, pitch 13.60 m (latitude 47.0°).

Yield of 1 kWp
1,246kWh/year
Tilt
37°2° east of south
10 kW
12,460kWh/year
Row pitch
13.60m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Nadbuzke

The designer opens with this place’s coordinates, latitude 47.0° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 10 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

45Jan63Feb106Mar128Apr142May141Jun152Jul152Aug128Sep99Oct53Nov38Dec

July: 152 kWh/kWp, December: 38 — 4.0 times less.

January: 45 against 38 in the oblast, 18.4% more.

Nadbuzke: plants, kWh
kWpA yearJulyDecember
56,230760190
1012,4601,520380
1518,6902,280570

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.