Solar plant: site data

Solar power plant in Myta, Stryiskyi Raion, Lviv Oblast

Myta: 1,012 kWh per kWp a year, tilt 36° 10° east of south (PVGIS). 6.6% below the oblast median (1,084). #268 of 286 in the rayon, #1499 of 1532 in the oblast.

Stryi, the rayon centre, is 54 km away. 776 m above sea level — above 500 m the DBN snow and wind are higher. 45 km away: Drohobych, the nearest bigger centre, 1,073 — 5.7% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 80 km. 10.95 m between rows, pitch 14.82 m (latitude 49.0°).

Yield of 1 kWp
1,012kWh/year
Tilt
36°10° east of south
10 kW
10,118kWh/year
Row pitch
14.82m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Myta

The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 80 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan55Feb86Mar106Apr113May116Jun124Jul124Aug100Sep76Oct43Nov29Dec

July: 124 kWh/kWp, December: 29 — 4.3 times less.

October: 76 against 84 in the oblast, 9.5% less.

Myta: plants, kWh
kWpA yearJulyDecember
55,059620145
1010,1181,240290
1515,1771,860435

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Stryiskyi RaionLviv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.