Solar plant: site data

Solar power plant in Klymets, Stryiskyi Raion, Lviv Oblast

Klymets: 1,064 kWh per kWp a year, tilt 37° 5° east of south (PVGIS). 1.8% below the oblast median (1,084). #224 of 286 in the rayon, #1314 of 1532 in the oblast.

Stryi, the rayon centre, is 68 km away. 778 m above sea level — above 500 m the DBN snow and wind are higher. 53 km away: Perechyn, the nearest bigger centre, 1,100 — 3.3% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 69 km. 11.09 m between rows, pitch 14.91 m (latitude 48.8°).

Yield of 1 kWp
1,064kWh/year
Tilt
37°5° east of south
10 kW
10,643kWh/year
Row pitch
14.91m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Klymets

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 69 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

42Jan58Feb92Mar109Apr118May123Jun130Jul131Aug105Sep80Oct46Nov30Dec

August: 131 kWh/kWp, December: 30 — 4.4 times less.

January: 42 against 39 in the oblast, 7.7% more.

Klymets: plants, kWh
kWpA yearAugustDecember
55,322655150
1010,6431,310300
1515,9651,965450

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Stryiskyi RaionLviv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.