Solar plant: site data

Solar power plant in Butyny, Sheptytskyi Raion, Lviv Oblast

Butyny: 1,089 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). Exactly the oblast median (1,084). #129 of 207 in the rayon, #541 of 1532 in the oblast.

Sheptytskyi, the rayon centre, is 26 km away. 207 m above sea level. 26 km away: Sheptytskyi, the nearest bigger centre, 1,079 — 0.9% more here. Snow and wind from the nearest regional centre in the DBN — Львів, 43 km. 12.59 m between rows, pitch 16.36 m (latitude 50.2°).

Yield of 1 kWp
1,089kWh/year
Tilt
38°2° east of south
10 kW
10,892kWh/year
Row pitch
16.36m · GCR 0.29
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,310 / 520Pa

Ground frame designer

A ground frame for a solar plant: Butyny

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Львів, 43 km: snow 1,310 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan57Feb95Mar115Apr125May128Jun133Jul132Aug107Sep83Oct43Nov32Dec

July: 133 kWh/kWp, December: 32 — 4.2 times less.

November: 43 against 44 in the oblast, 2.3% less.

Butyny: plants, kWh
kWpA yearJulyDecember
55,446665160
1010,8921,330320
1516,3381,995480

Snow and wind: Львів

Example: a 10 kW ground frame

For the loads of Lviv: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Sheptytskyi RaionLviv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.