Solar plant: site data

Solar power plant in Bahnuvate, Sambirskyi Raion, Lviv Oblast

Bahnuvate: 998 kWh per kWp a year, tilt 37° 1° west of south (PVGIS). 8.0% below the oblast median (1,084). #259 of 264 in the rayon, #1511 of 1532 in the oblast.

Sambir, the rayon centre, is 51 km away. 709 m above sea level — above 500 m the DBN snow and wind are higher. 42 km away: Drohobych, the nearest bigger centre, 1,073 — 7.1% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 79 km. 11.26 m between rows, pitch 15.08 m (latitude 49.1°).

Yield of 1 kWp
998kWh/year
Tilt
37°1° west of south
10 kW
9,975kWh/year
Row pitch
15.08m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Bahnuvate

The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 79 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan53Feb84Mar102Apr111May114Jun122Jul122Aug98Sep78Oct45Nov30Dec

July: 122 kWh/kWp, December: 30 — 4.1 times less.

April: 102 against 114 in the oblast, 10.5% less.

Bahnuvate: plants, kWh
kWpA yearJulyDecember
54,988610150
109,9751,220300
1514,9631,830450

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.