Solar plant: site data

Solar power plant in Yehorivka, Rovenkivskyi Raion, Luhansk Oblast

Yehorivka: 1,165 kWh per kWp a year, tilt 36° facing south (PVGIS). 1.3% above the oblast median (1,150). #3 of 96 in the rayon, #15 of 964 in the oblast.

Rovenky, the rayon centre, is 18 km away. 84 m above sea level. 18 km away: Rovenky, the nearest bigger centre, 1,157 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 302 km. 10.20 m between rows, pitch 14.07 m (latitude 48.0°).

Yield of 1 kWp
1,165kWh/year
Tilt
36°facing south
10 kW
11,645kWh/year
Row pitch
14.07m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Yehorivka

The designer opens with this place’s coordinates, latitude 48.0° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 302 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan54Feb89Mar117Apr138May142Jun147Jul150Aug125Sep90Oct48Nov29Dec

August: 150 kWh/kWp, December: 29 — 5.2 times less.

November: 48 against 43 in the oblast, 11.6% more.

Yehorivka: plants, kWh
kWpA yearAugustDecember
55,823750145
1011,6451,500290
1517,4682,250435

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Rovenkivskyi RaionLuhansk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.