Solar plant: site data

Solar power plant in Rannia Zoria, Starobilskyi Raion, Luhansk Oblast

Rannia Zoria: 1,143 kWh per kWp a year, tilt 37° facing south (PVGIS). 0.6% below the oblast median (1,150). #67 of 201 in the rayon, #631 of 964 in the oblast.

Starobilsk, the rayon centre, is 94 km away. 173 m above sea level. 93 km away: Novoaidar, the nearest bigger centre, 1,155 — 1.0% less here. Snow and wind from the nearest regional centre in the DBN — Харків, 298 km. 11.43 m between rows, pitch 15.25 m (latitude 49.3°).

Yield of 1 kWp
1,143kWh/year
Tilt
37°facing south
10 kW
11,434kWh/year
Row pitch
15.25m · GCR 0.31
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,600 / 430Pa

Ground frame designer

A ground frame for a solar plant: Rannia Zoria

The designer opens with this place’s coordinates, latitude 49.3° for the row spacing and the DBN loads of the nearest regional centre — Харків, 298 km: snow 1,600 Pa, wind 430 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan56Feb85Mar117Apr140May143Jun146Jul147Aug121Sep83Oct42Nov25Dec

August: 147 kWh/kWp, December: 25 — 5.9 times less.

December: 25 against 26 in the oblast, 3.8% less.

Rannia Zoria: plants, kWh
kWpA yearAugustDecember
55,717735125
1011,4341,470250
1517,1512,205375

Snow and wind: Харків

Example: a 10 kW ground frame

For the loads of Kharkiv: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Starobilskyi RaionLuhansk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.