Solar plant: site data

Solar power plant in Nezhuryne, Svativskyi Raion, Luhansk Oblast

Nezhuryne: 1,139 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.0% below the oblast median (1,150). #50 of 189 in the rayon, #743 of 964 in the oblast.

Svatove, the rayon centre, is 8 km away. 170 m above sea level. 8 km away: Svatove, the nearest bigger centre, 1,131 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Харків, 148 km. 11.26 m between rows, pitch 15.13 m (latitude 49.4°).

Yield of 1 kWp
1,139kWh/year
Tilt
36°1° east of south
10 kW
11,385kWh/year
Row pitch
15.13m · GCR 0.32
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,600 / 430Pa

Ground frame designer

A ground frame for a solar plant: Nezhuryne

The designer opens with this place’s coordinates, latitude 49.4° for the row spacing and the DBN loads of the nearest regional centre — Харків, 148 km: snow 1,600 Pa, wind 430 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan55Feb87Mar116Apr136May143Jun147Jul147Aug120Sep83Oct40Nov25Dec

July: 147 kWh/kWp, December: 25 — 5.9 times less.

November: 40 against 43 in the oblast, 7.0% less.

Nezhuryne: plants, kWh
kWpA yearJulyDecember
55,693735125
1011,3851,470250
1517,0782,205375

Snow and wind: Харків

Example: a 10 kW ground frame

For the loads of Kharkiv: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Svativskyi RaionLuhansk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.