Solar plant: site data
Solar power plant in Hrybuvakha, Rovenkivskyi Raion, Luhansk Oblast
Hrybuvakha: 1,149 kWh per kWp a year, tilt 35° 4° east of south (PVGIS). Exactly the oblast median (1,150). #96 of 96 in the rayon, #529 of 964 in the oblast.
Rovenky, the rayon centre, is 12 km away. 119 m above sea level. 12 km away: Rovenky, the nearest bigger centre, 1,157 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 312 km. 9.95 m between rows, pitch 13.87 m (latitude 48.0°).
- Yield of 1 kWp
- 1,149kWh/year
- Tilt
- 35°4° east of south
- 10 kW
- 11,485kWh/year
- Row pitch
- 13.87m · GCR 0.34
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,110 / 460Pa
Ground frame designer
A ground frame for a solar plant: Hrybuvakha
The designer opens with this place’s coordinates, latitude 48.0° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 312 km: snow 1,110 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 149 kWh/kWp, December: 25 — 6.0 times less.
February: 51 against 56 in the oblast, 8.9% less.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 5,743 | 745 | 125 |
| 10 | 11,485 | 1,490 | 250 |
| 15 | 17,228 | 2,235 | 375 |
Example: a 10 kW ground frame
For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.
How these numbers are computed
Nearby
- Blahivka3 km1,159 kWh/kWp
- Platonivka4 km1,161 kWh/kWp
- Ulianivka4 km1,153 kWh/kWp
- Novodarivka5 km1,159 kWh/kWp
- Novokrasnivka6 km1,162 kWh/kWp
- Marivka6 km1,160 kWh/kWp
All places: Rovenkivskyi RaionLuhansk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.