Solar plant: site data

Solar power plant in Novyi Svit, Feodosiiskyi Raion, Autonomous Republic of Crimea

Novyi Svit: 1,337 kWh per kWp a year, tilt 35° 2° east of south (PVGIS). 4.1% above the oblast median (1,284). #6 of 113 in the rayon, #83 of 1025 in the oblast.

Feodosiya, the rayon centre, is 43 km away. 33 m above sea level. 5 km away: Sudak, the nearest bigger centre, the same 1,340. Snow and wind from the nearest regional centre in the DBN — Херсон, 269 km. 8.17 m between rows, pitch 12.09 m (latitude 44.8°).

Yield of 1 kWp
1,337kWh/year
Tilt
35°2° east of south
10 kW
13,368kWh/year
Row pitch
12.09m · GCR 0.40
T_min
-27 °Cregion V, Crimean Mountains
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Novyi Svit

The designer opens with this place’s coordinates, latitude 44.8° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 269 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

53Jan71Feb106Mar132Apr147May151Jun161Jul160Aug135Sep103Oct67Nov49Dec

July: 161 kWh/kWp, December: 49 — 3.3 times less.

January: 53 against 47 in the oblast, 12.8% more.

Novyi Svit: plants, kWh
kWpA yearJulyDecember
56,684805245
1013,3681,610490
1520,0522,415735

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Feodosiiskyi RaionAutonomous Republic of Crimea: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.