Solar plant: site data

Solar power plant in Gorlinka, Bilohirskyi Raion, Autonomous Republic of Crimea

Gorlinka: 1,238 kWh per kWp a year, tilt 35° 2° east of south (PVGIS). 3.6% below the oblast median (1,284). #120 of 139 in the rayon, #997 of 1025 in the oblast.

Bilohirsk, the rayon centre, is 13 km away. 294 m above sea level. 13 km away: Bilohirsk, the nearest bigger centre, 1,261 — 1.8% less here. Snow and wind from the nearest regional centre in the DBN — Херсон, 245 km. 8.25 m between rows, pitch 12.17 m (latitude 45.0°).

Yield of 1 kWp
1,238kWh/year
Tilt
35°2° east of south
10 kW
12,383kWh/year
Row pitch
12.17m · GCR 0.39
T_min
-27 °Cregion V, Crimean Mountains
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Gorlinka

The designer opens with this place’s coordinates, latitude 45.0° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 245 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

50Jan64Feb97Mar122Apr138May138Jun147Jul151Aug124Sep97Oct63Nov47Dec

August: 151 kWh/kWp, December: 47 — 3.2 times less.

March: 97 against 106 in the oblast, 8.5% less.

Gorlinka: plants, kWh
kWpA yearAugustDecember
56,192755235
1012,3831,510470
1518,5752,265705

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bilohirskyi RaionAutonomous Republic of Crimea: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.