Solar plant: site data
Solar power plant in Slobidka-Kulchiievetska, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast
Slobidka-Kulchiievetska: 1,134 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 3.0% above the oblast median (1,100). #86 of 226 in the rayon, #86 of 1109 in the oblast.
Kamyanets-Podilskyi, the rayon centre, is 6 km away. 226 m above sea level. 6 km away: Kamyanets-Podilskyi, the nearest bigger centre, the same 1,129. Snow and wind from the nearest regional centre in the DBN — Чернівці, 67 km. 10.69 m between rows, pitch 14.56 m (latitude 48.7°).
- Yield of 1 kWp
- 1,134kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 11,336kWh/year
- Row pitch
- 14.56m · GCR 0.33
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,320 / 500Pa
Ground frame designer
A ground frame for a solar plant: Slobidka-Kulchiievetska
The designer opens with this place’s coordinates, latitude 48.7° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 67 km: snow 1,320 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 142 kWh/kWp, December: 35 — 4.1 times less.
December: 35 against 29 in the oblast, 20.7% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,668 | 710 | 175 |
| 10 | 11,336 | 1,420 | 350 |
| 15 | 17,004 | 2,130 | 525 |
Example: a 10 kW ground frame
For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.
How these numbers are computed
Nearby
- Muksha Kytaihorodska3 km1,130 kWh/kWp
- Kulchiivtsi4 km1,140 kWh/kWp
- Kalinya6 km1,140 kWh/kWp
- Kamyanets-Podilskyi6 km1,129 kWh/kWp
- Panivtsi6 km1,133 kWh/kWp
- Bahovytsia7 km1,139 kWh/kWp
All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.