Solar plant: site data

Solar power plant in Nemirintsy, Khmelnytskyi Raion, Khmelnytskyi Oblast

Nemirintsy: 1,080 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.8% below the oblast median (1,100). #531 of 576 in the rayon, #1027 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 52 km away. 279 m above sea level. 7 km away: Volochysk, the nearest bigger centre, the same 1,083. Snow and wind from the nearest regional centre in the DBN — Тернопіль, 49 km. 11.35 m between rows, pitch 15.22 m (latitude 49.5°).

Yield of 1 kWp
1,080kWh/year
Tilt
36°2° east of south
10 kW
10,802kWh/year
Row pitch
15.22m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,390 / 520Pa

Ground frame designer

A ground frame for a solar plant: Nemirintsy

The designer opens with this place’s coordinates, latitude 49.5° for the row spacing and the DBN loads of the nearest regional centre — Тернопіль, 49 km: snow 1,390 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

29Jan46Feb86Mar116Apr133May135Jun139Jul137Aug112Sep83Oct37Nov28Dec

July: 139 kWh/kWp, December: 28 — 5.0 times less.

February: 46 against 51 in the oblast, 9.8% less.

Nemirintsy: plants, kWh
kWpA yearJulyDecember
55,401695140
1010,8021,390280
1516,2032,085420

Snow and wind: Тернопіль

Example: a 10 kW ground frame

For the loads of Ternopil: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.