Solar plant: site data
Solar power plant in Voznesenka, Henicheskyi Raion, Kherson Oblast
Voznesenka: 1,290 kWh per kWp a year, tilt 36° facing south (PVGIS). 3.0% above the oblast median (1,253). #27 of 167 in the rayon, #143 of 711 in the oblast.
Henichesk, the rayon centre, is 46 km away. 12 m above sea level. 45 km away: Armyansk, the nearest bigger centre, 1,317 — 2.0% less here. Snow and wind from the nearest regional centre in the DBN — Херсон, 130 km. 9.12 m between rows, pitch 12.99 m (latitude 46.3°).
- Yield of 1 kWp
- 1,290kWh/year
- Tilt
- 36°facing south
- 10 kW
- 12,904kWh/year
- Row pitch
- 12.99m · GCR 0.37
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 760 / 480Pa
Ground frame designer
A ground frame for a solar plant: Voznesenka
The designer opens with this place’s coordinates, latitude 46.3° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 130 km: snow 760 Pa, wind 480 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 157 kWh/kWp, December: 41 — 3.8 times less.
December: 41 against 37 in the oblast, 10.8% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 6,452 | 785 | 205 |
| 10 | 12,904 | 1,570 | 410 |
| 15 | 19,356 | 2,355 | 615 |
Example: a 10 kW ground frame
For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.
How these numbers are computed
Nearby
- Blahovishchenka4 km1,291 kWh/kWp
- Serhiivka6 km1,278 kWh/kWp
- Zakharivka7 km1,286 kWh/kWp
- Zaozerne7 km1,289 kWh/kWp
- Voskresenka9 km1,279 kWh/kWp
- Hromivka11 km1,282 kWh/kWp
All places: Henicheskyi RaionKherson Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.