Solar plant: site data
Solar power plant in Kalynivka, Henicheskyi Raion, Kherson Oblast
Kalynivka: 1,278 kWh per kWp a year, tilt 36° facing south (PVGIS). 2.0% above the oblast median (1,253). #47 of 167 in the rayon, #184 of 711 in the oblast.
Henichesk, the rayon centre, is 33 km away. 19 m above sea level. 33 km away: Henichesk, the nearest bigger centre, 1,260 — 1.4% more here. Snow and wind from the nearest regional centre in the DBN — Херсон, 144 km. 9.15 m between rows, pitch 13.02 m (latitude 46.3°).
- Yield of 1 kWp
- 1,278kWh/year
- Tilt
- 36°facing south
- 10 kW
- 12,784kWh/year
- Row pitch
- 13.02m · GCR 0.37
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 760 / 480Pa
Ground frame designer
A ground frame for a solar plant: Kalynivka
The designer opens with this place’s coordinates, latitude 46.3° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 144 km: snow 760 Pa, wind 480 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 156 kWh/kWp, December: 39 — 4.0 times less.
December: 39 against 37 in the oblast, 5.4% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 6,392 | 780 | 195 |
| 10 | 12,784 | 1,560 | 390 |
| 15 | 19,176 | 2,340 | 585 |
Example: a 10 kW ground frame
For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.
How these numbers are computed
Nearby
- Sadove5 km1,295 kWh/kWp
- Maiachka6 km1,287 kWh/kWp
- Oleksandrivka6 km1,265 kWh/kWp
- Syvashivka6 km1,295 kWh/kWp
- Odradivka7 km1,270 kWh/kWp
- Novotroyitske9 km1,275 kWh/kWp
All places: Henicheskyi RaionKherson Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.