Solar plant: site data
Solar power plant in Vyzhnii Bereziv, Kosivskyi Raion, Ivano-Frankivsk Oblast
Vyzhnii Bereziv: 1,095 kWh per kWp a year, tilt 39° 8° east of south (PVGIS). Exactly the oblast median (1,097). #21 of 41 in the rayon, #373 of 700 in the oblast.
Kosiv, the rayon centre, is 25 km away. 531 m above sea level — above 500 m the DBN snow and wind are higher. 23 km away: Kolomyia, the nearest bigger centre, 1,120 — 2.2% less here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 57 km. 11.24 m between rows, pitch 14.96 m (latitude 48.4°).
- Yield of 1 kWp
- 1,095kWh/year
- Tilt
- 39°8° east of south
- 10 kW
- 10,953kWh/year
- Row pitch
- 14.96m · GCR 0.32
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,410 / 500Pa
Ground frame designer
A ground frame for a solar plant: Vyzhnii Bereziv
The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 57 km: snow 1,410 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 124 kWh/kWp, December: 45 — 2.8 times less.
January: 55 against 46 in the oblast, 19.6% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,477 | 620 | 225 |
| 10 | 10,953 | 1,240 | 450 |
| 15 | 16,430 | 1,860 | 675 |
Snow and wind: Івано-Франківськ
Example: a 10 kW ground frame
For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.
How these numbers are computed
Nearby
- Bania-Bereziv2 km1,096 kWh/kWp
- Serednii Bereziv3 km1,088 kWh/kWp
- Tekuche3 km1,081 kWh/kWp
- Liuchky4 km1,070 kWh/kWp
- Nyzhnii Bereziv5 km1,059 kWh/kWp
- Sloboda6 km1,092 kWh/kWp
All places: Kosivskyi RaionIvano-Frankivsk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.