Solar plant: site data

Solar power plant in Cheremoshna, Verkhovynskyi Raion, Ivano-Frankivsk Oblast

Cheremoshna: 1,059 kWh per kWp a year, tilt 38° 15° east of south (PVGIS). 3.5% below the oblast median (1,097). #22 of 41 in the rayon, #602 of 700 in the oblast.

Verkhovyna, the rayon centre, is 15 km away. 575 m above sea level — above 500 m the DBN snow and wind are higher. 15 km away: Verkhovyna, the nearest bigger centre, 1,074 — 1.4% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 80 km. 10.72 m between rows, pitch 14.49 m (latitude 48.0°).

Yield of 1 kWp
1,059kWh/year
Tilt
38°15° east of south
10 kW
10,588kWh/year
Row pitch
14.49m · GCR 0.33
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Cheremoshna

The designer opens with this place’s coordinates, latitude 48.0° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 80 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

50Jan64Feb91Mar104Apr111May112Jun123Jul121Aug102Sep83Oct55Nov42Dec

July: 123 kWh/kWp, December: 42 — 2.9 times less.

November: 55 against 48 in the oblast, 14.6% more.

Cheremoshna: plants, kWh
kWpA yearJulyDecember
55,294615210
1010,5881,230420
1515,8821,845630

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Verkhovynskyi RaionIvano-Frankivsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.