Solar power plant in Santiago de Compostela, Spain: yield, tilt angle and row spacing

Santiago de Compostela: 1,301 kWh per kWp a year at the optimal tilt of 35°, 4° west of south (PVGIS). 19.5% below the median of the main cities of Spain (1,615). #134 of 147 main cities of Spain by yield. For comparison, Kyiv: 1,114 kWh/kWp — 16.8% more here.

Santiago de Compostela is in the province of A Coruña, Galicia. Population 99,536 (GeoNames). 257 m above sea level. 56 km away: A Coruña, the nearest bigger city, 1,282 kWh/kWp — 1.5% more here. 7.33 m between rows, pitch 11.25 m, GCR 0.43 (latitude 42.9°).

Yield of 1 kWp
1,301kWh/year
Tilt
35°4° west of south
10 kW
13,007kWh/year
Row pitch
11.25m · GCR 0.43
Rank in the country
134of 147 cities

Ground frame designer

A ground frame for a solar plant: Santiago de Compostela

Latitude 42.9°: the tilt and the row pitch follow it. Enter the snow and wind for Spain in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

69Jan86Feb111Mar122Apr135May131Jun145Jul143Aug125Sep96Oct70Nov67Dec

July: 145 kWh/kWp, December: 67 — 2.2 times less.

January: 69 against the median of 109 for the main cities of Spain, 36.7% less.

Santiago de Compostela: plants, kWh
kWpA yearJulyDecember
56,504725335
1013,0071,450670
1519,5112,1751,005

Fixed tilt facing south

What a table yields at another tilt than the optimal 35° — for roofs and frames with a standard slope.

Santiago de Compostela: yield at a fixed tilt, kWh/kWp
TiltA yearAgainst the optimum
35° (optimum)1,301—
15°1,236−5.0%
30°1,295−0.4%
45°1,287−1.0%
90°870−33.1%

Snow and wind loads

Snow and wind loads for a site in Spain follow CTE DB SE-AE (Spain’s Código Técnico de la Edificación) and, where the Eurocodes are applied, UNE-EN 1991-1-3 and UNE-EN 1991-1-4 with the Spanish National Annex. Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Spain: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.