Solar plant: site data

Solar power plant in Shevchenko, Pokrovskyi Raion, Donetsk Oblast

Shevchenko: 1,161 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). Exactly the oblast median (1,161). #120 of 262 in the rayon, #673 of 1312 in the oblast.

Pokrovsk, the rayon centre, is 7 km away. 184 m above sea level. 7 km away: Pokrovsk, the nearest bigger centre, the same 1,159. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 154 km. 10.37 m between rows, pitch 14.24 m (latitude 48.2°).

Yield of 1 kWp
1,161kWh/year
Tilt
36°1° east of south
10 kW
11,609kWh/year
Row pitch
14.24m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Shevchenko

The designer opens with this place’s coordinates, latitude 48.2° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 154 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan54Feb92Mar114Apr137May143Jun147Jul150Aug124Sep91Oct47Nov27Dec

August: 150 kWh/kWp, December: 27 — 5.6 times less.

January: 35 against 37 in the oblast, 5.4% less.

Shevchenko: plants, kWh
kWpA yearAugustDecember
55,805750135
1011,6091,500270
1517,4142,250405

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Pokrovskyi RaionDonetsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.