Solar plant: site data
Solar power plant in Shevchenko, Kalmiuskyi Raion, Donetsk Oblast
Shevchenko: 1,181 kWh per kWp a year, tilt 35° 1° west of south (PVGIS). 1.7% above the oblast median (1,161). #94 of 174 in the rayon, #227 of 1312 in the oblast.
Boykivske, the rayon centre, is 20 km away. 72 m above sea level. 20 km away: Boykivske, the nearest bigger centre, 1,189 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 236 km. 9.64 m between rows, pitch 13.56 m (latitude 47.5°).
- Yield of 1 kWp
- 1,181kWh/year
- Tilt
- 35°1° west of south
- 10 kW
- 11,810kWh/year
- Row pitch
- 13.56m · GCR 0.35
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,110 / 460Pa
Ground frame designer
A ground frame for a solar plant: Shevchenko
The designer opens with this place’s coordinates, latitude 47.5° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 236 km: snow 1,110 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 153 kWh/kWp, December: 30 — 5.1 times less.
January: 33 against 37 in the oblast, 10.8% less.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 5,905 | 765 | 150 |
| 10 | 11,810 | 1,530 | 300 |
| 15 | 17,715 | 2,295 | 450 |
Example: a 10 kW ground frame
For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.
How these numbers are computed
Nearby
- Kotliarivske5 km1,180 kWh/kWp
- Chyrylyans'ke5 km1,184 kWh/kWp
- Hlynka6 km1,176 kWh/kWp
- Kuznetsovo-Mykhailivka6 km1,182 kWh/kWp
- Oleksandropil8 km1,178 kWh/kWp
- Vershynivka9 km1,186 kWh/kWp
All places: Kalmiuskyi RaionDonetsk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.