Solar plant: site data

Solar power plant in Hirne, Donetskyi Raion, Donetsk Oblast

Hirne: 1,155 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 0.6% below the oblast median (1,161). #154 of 157 in the rayon, #956 of 1312 in the oblast.

Donetsk, the rayon centre, is 30 km away. 220 m above sea level. 20 km away: Makiyivka, the nearest bigger centre, 1,167 — 1.0% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 229 km. 10.25 m between rows, pitch 14.12 m (latitude 48.1°).

Yield of 1 kWp
1,155kWh/year
Tilt
36°1° east of south
10 kW
11,549kWh/year
Row pitch
14.12m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Hirne

The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 229 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan53Feb89Mar115Apr136May141Jun147Jul148Aug124Sep89Oct46Nov28Dec

August: 148 kWh/kWp, December: 28 — 5.3 times less.

February: 53 against 55 in the oblast, 3.6% less.

Hirne: plants, kWh
kWpA yearAugustDecember
55,775740140
1011,5491,480280
1517,3242,220420

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Donetskyi RaionDonetsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.