Solar plant: site data

Solar power plant in Bert, Kalmiuskyi Raion, Donetsk Oblast

Bert: 1,204 kWh per kWp a year, tilt 35° 2° west of south (PVGIS). 3.7% above the oblast median (1,161). #59 of 174 in the rayon, #138 of 1312 in the oblast.

Boykivske, the rayon centre, is 12 km away. 88 m above sea level. 12 km away: Boykivske, the nearest bigger centre, 1,189 — 1.3% more here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 219 km. 9.52 m between rows, pitch 13.44 m (latitude 47.3°).

Yield of 1 kWp
1,204kWh/year
Tilt
35°2° west of south
10 kW
12,043kWh/year
Row pitch
13.44m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Bert

The designer opens with this place’s coordinates, latitude 47.3° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 219 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan55Feb95Mar122Apr141May145Jun152Jul154Aug127Sep95Oct52Nov31Dec

August: 154 kWh/kWp, December: 31 — 5.0 times less.

December: 31 against 28 in the oblast, 10.7% more.

Bert: plants, kWh
kWpA yearAugustDecember
56,022770155
1012,0431,540310
1518,0652,310465

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kalmiuskyi RaionDonetsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.