Solar plant: site data

Solar power plant in Zaplavka, Samarivskyi Raion, Dnipropetrovsk Oblast

Zaplavka: 1,151 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 2.2% below the oblast median (1,177). #111 of 115 in the rayon, #1492 of 1501 in the oblast.

Samar, the rayon centre, is 57 km away. 84 m above sea level. 32 km away: Tsarychanka, the nearest bigger centre, 1,170 — 1.6% less here. Snow and wind from the nearest regional centre in the DBN — Полтава, 62 km. 11.01 m between rows, pitch 14.88 m (latitude 49.1°).

Yield of 1 kWp
1,151kWh/year
Tilt
36°2° east of south
10 kW
11,509kWh/year
Row pitch
14.88m · GCR 0.32
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,450 / 470Pa

Ground frame designer

A ground frame for a solar plant: Zaplavka

The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 62 km: snow 1,450 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan52Feb92Mar116Apr138May143Jun150Jul149Aug120Sep88Oct42Nov27Dec

July: 150 kWh/kWp, December: 27 — 5.6 times less.

November: 42 against 47 in the oblast, 10.6% less.

Zaplavka: plants, kWh
kWpA yearJulyDecember
55,755750135
1011,5091,500270
1517,2642,250405

Snow and wind: Полтава

Example: a 10 kW ground frame

For the loads of Poltava: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Samarivskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.