Germany: solar plant site data

Solar power plant in Lippstadt, Germany: yield, tilt angle and row spacing

Lippstadt: 1,053 kWh per kWp a year at the optimal tilt of 40°, 1° east of south (PVGIS). 0.8% above the median of the main cities of Germany (1,045). #87 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 5.4% less here.

Lippstadt is in North Rhine-Westphalia. Population 67,219 (GeoNames). 81 m above sea level. 26 km away: Gütersloh, the nearest bigger city, 1,016 kWh/kWp — 3.6% more here. 14.82 m between rows, pitch 18.48 m, GCR 0.26 (latitude 51.7°).

Yield of 1 kWp
1,053kWh/year
Tilt
40°1° east of south
10 kW
10,534kWh/year
Row pitch
18.48m · GCR 0.26
Rank in the country
87of 193 cities

Ground frame designer

A ground frame for a solar plant: Lippstadt

Latitude 51.7°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan56Feb94Mar118Apr127May127Jun124Jul118Aug101Sep76Oct45Nov32Dec

May: 127 kWh/kWp, December: 32 — 4.0 times less.

December: 32 against the median of 30 for the main cities of Germany, 6.7% more.

Lippstadt: plants, kWh
kWpA yearMayDecember
55,267635160
1010,5341,270320
1515,8011,905480

Snow and wind loads

Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Germany: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.