Solar plant: site data
Solar power plant in Vikno, Chernivetskyi Raion, Chernivtsi Oblast
Vikno: 1,132 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.9% below the oblast median (1,143). #175 of 215 in the rayon, #297 of 422 in the oblast.
Chernivtsi, the rayon centre, is 31 km away. 194 m above sea level. 11 km away: Zastavna, the nearest bigger centre, the same 1,131. Snow and wind from the nearest regional centre in the DBN — Чернівці, 31 km. 10.88 m between rows, pitch 14.70 m (latitude 48.6°).
- Yield of 1 kWp
- 1,132kWh/year
- Tilt
- 37°2° east of south
- 10 kW
- 11,322kWh/year
- Row pitch
- 14.70m · GCR 0.33
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,320 / 500Pa
Ground frame designer
A ground frame for a solar plant: Vikno
The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 31 km: snow 1,320 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 139 kWh/kWp, December: 34 — 4.1 times less.
December: 34 against 37 in the oblast, 8.1% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,661 | 695 | 170 |
| 10 | 11,322 | 1,390 | 340 |
| 15 | 16,983 | 2,085 | 510 |
Example: a 10 kW ground frame
For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.
How these numbers are computed
Nearby
- Pohorilivka3 km1,135 kWh/kWp
- Zazulyntsi5 km1,124 kWh/kWp
- Mytkiv5 km1,131 kWh/kWp
- Chotnyy Potik5 km1,118 kWh/kWp
- Bridok5 km1,135 kWh/kWp
- Synkiv5 km1,136 kWh/kWp
All places: Chernivetskyi RaionChernivtsi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.