Solar plant: site data

Solar power plant in Myhove, Vyzhnytskyi Raion, Chernivtsi Oblast

Myhove: 1,125 kWh per kWp a year, tilt 39° 4° east of south (PVGIS). 1.6% below the oblast median (1,143). #25 of 94 in the rayon, #326 of 422 in the oblast.

Vyzhnytsya, the rayon centre, is 17 km away. 505 m above sea level — above 500 m the DBN snow and wind are higher. 17 km away: Vyzhnytsya, the nearest bigger centre, 1,076 — 4.5% more here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 44 km. 11.05 m between rows, pitch 14.77 m (latitude 48.2°).

Yield of 1 kWp
1,125kWh/year
Tilt
39°4° east of south
10 kW
11,246kWh/year
Row pitch
14.77m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Myhove

The designer opens with this place’s coordinates, latitude 48.2° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 44 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

58Jan67Feb96Mar108Apr118May117Jun129Jul127Aug108Sep90Oct58Nov49Dec

July: 129 kWh/kWp, December: 49 — 2.6 times less.

December: 49 against 37 in the oblast, 32.4% more.

Myhove: plants, kWh
kWpA yearJulyDecember
55,623645245
1011,2461,290490
1516,8691,935735

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Vyzhnytskyi RaionChernivtsi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.