Solar plant: site data
Solar power plant in Bahna, Vyzhnytskyi Raion, Chernivtsi Oblast
Bahna: 1,085 kWh per kWp a year, tilt 39° 9° east of south (PVGIS). 5.0% below the oblast median (1,143). #58 of 94 in the rayon, #385 of 422 in the oblast.
Vyzhnytsya, the rayon centre, is 4 km away. 457 m above sea level. 4 km away: Vyzhnytsya, the nearest bigger centre, 1,076 — 0.8% more here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 53 km. 11.10 m between rows, pitch 14.82 m (latitude 48.2°).
- Yield of 1 kWp
- 1,085kWh/year
- Tilt
- 39°9° east of south
- 10 kW
- 10,854kWh/year
- Row pitch
- 14.82m · GCR 0.32
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,320 / 500Pa
Ground frame designer
A ground frame for a solar plant: Bahna
The designer opens with this place’s coordinates, latitude 48.2° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 53 km: snow 1,320 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 125 kWh/kWp, December: 46 — 2.7 times less.
December: 46 against 37 in the oblast, 24.3% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,427 | 625 | 230 |
| 10 | 10,854 | 1,250 | 460 |
| 15 | 16,281 | 1,875 | 690 |
Example: a 10 kW ground frame
For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.
How these numbers are computed
Nearby
- Chereshenka3 km1,116 kWh/kWp
- Vyzhenka4 km1,078 kWh/kWp
- Vyzhnytsya4 km1,076 kWh/kWp
- Chornohuzy5 km1,116 kWh/kWp
- Kuty6 km1,120 kWh/kWp
- Khorovy7 km1,081 kWh/kWp
All places: Vyzhnytskyi RaionChernivtsi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.