Solar plant: site data

Solar power plant in Lovyn, Chernihivskyi Raion, Chernihiv Oblast

Lovyn: 1,075 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). 3.0% below the oblast median (1,108). #452 of 479 in the rayon, #1502 of 1558 in the oblast.

Chernihiv, the rayon centre, is 43 km away. 134 m above sea level. 43 km away: Chernihiv, the nearest bigger centre, 1,105 — 2.8% less here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 45 km. 14.46 m between rows, pitch 18.23 m (latitude 51.9°).

Yield of 1 kWp
1,075kWh/year
Tilt
38°2° east of south
10 kW
10,745kWh/year
Row pitch
18.23m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Lovyn

The designer opens with this place’s coordinates, latitude 51.9° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 45 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan54Feb94Mar115Apr135May140Jun138Jul133Aug107Sep71Oct29Nov23Dec

June: 140 kWh/kWp, December: 23 — 6.1 times less.

November: 29 against 33 in the oblast, 12.1% less.

Lovyn: plants, kWh
kWpA yearJuneDecember
55,373700115
1010,7451,400230
1516,1182,100345

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chernihivskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.