Solar plant: site data
Solar power plant in Lisne, Chernihivskyi Raion, Chernihiv Oblast
Lisne: 1,084 kWh per kWp a year, tilt 38° 3° east of south (PVGIS). 2.2% below the oblast median (1,108). #412 of 479 in the rayon, #1329 of 1558 in the oblast.
Chernihiv, the rayon centre, is 46 km away. 120 m above sea level. 46 km away: Chernihiv, the nearest bigger centre, 1,105 — 1.9% less here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 45 km. 13.75 m between rows, pitch 17.52 m (latitude 51.3°).
- Yield of 1 kWp
- 1,084kWh/year
- Tilt
- 38°3° east of south
- 10 kW
- 10,840kWh/year
- Row pitch
- 17.52m · GCR 0.27
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,720 / 410Pa
Ground frame designer
A ground frame for a solar plant: Lisne
The designer opens with this place’s coordinates, latitude 51.3° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 45 km: snow 1,720 Pa, wind 410 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 139 kWh/kWp, December: 25 — 5.6 times less.
July: 136 against 142 in the oblast, 4.2% less.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,420 | 695 | 125 |
| 10 | 10,840 | 1,390 | 250 |
| 15 | 16,260 | 2,085 | 375 |
Example: a 10 kW ground frame
For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.
How these numbers are computed
Nearby
- Khatylova Huta1 km1,092 kWh/kWp
- Povidov2 km1,092 kWh/kWp
- Borovyky3 km1,089 kWh/kWp
- Vasyleva Huta3 km1,089 kWh/kWp
- Zahatka3 km1,093 kWh/kWp
- Prokhoriv4 km1,098 kWh/kWp
All places: Chernihivskyi RaionChernihiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.