Solar plant: site data

Solar power plant in Ivankiv, Novhorod-Siverskyi Raion, Chernihiv Oblast

Ivankiv: 1,096 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). 1.1% below the oblast median (1,108). #61 of 247 in the rayon, #1086 of 1558 in the oblast.

Novhorod-Siverskyi, the rayon centre, is 38 km away. 189 m above sea level. 38 km away: Novhorod-Siverskyi, the nearest bigger centre, 1,083 — 1.1% more here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 119 km. 14.56 m between rows, pitch 18.28 m (latitude 51.7°).

Yield of 1 kWp
1,096kWh/year
Tilt
39°2° east of south
10 kW
10,957kWh/year
Row pitch
18.28m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Ivankiv

The designer opens with this place’s coordinates, latitude 51.7° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 119 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan58Feb100Mar113Apr138May140Jun138Jul135Aug107Sep72Oct32Nov25Dec

June: 140 kWh/kWp, December: 25 — 5.6 times less.

January: 37 against 35 in the oblast, 5.7% more.

Ivankiv: plants, kWh
kWpA yearJuneDecember
55,479700125
1010,9571,400250
1516,4362,100375

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Novhorod-Siverskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.