Solar plant: site data

Solar power plant in Verkhnyachka, Umanskyi Raion, Cherkasy Oblast

Verkhnyachka: 1,140 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). Exactly the oblast median (1,144). #79 of 167 in the rayon, #489 of 731 in the oblast.

Uman, the rayon centre, is 16 km away. 231 m above sea level. 16 km away: Uman, the nearest bigger centre, 1,160 — 1.7% less here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 123 km. 10.82 m between rows, pitch 14.69 m (latitude 48.8°).

Yield of 1 kWp
1,140kWh/year
Tilt
36°2° east of south
10 kW
11,402kWh/year
Row pitch
14.69m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Verkhnyachka

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 123 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

32Jan52Feb91Mar119Apr137May143Jun148Jul144Aug117Sep88Oct40Nov29Dec

July: 148 kWh/kWp, December: 29 — 5.1 times less.

January: 32 against 35 in the oblast, 8.6% less.

Verkhnyachka: plants, kWh
kWpA yearJulyDecember
55,701740145
1011,4021,480290
1517,1032,220435

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Umanskyi RaionCherkasy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.