Solar plant: site data
Solar power plant in Skrypchyntsi, Zvenyhorodskyi Raion, Cherkasy Oblast
Skrypchyntsi: 1,143 kWh per kWp a year, tilt 37° 4° east of south (PVGIS). Exactly the oblast median (1,144). #83 of 197 in the rayon, #395 of 731 in the oblast.
Shpola, the rayon centre, is 49 km away. 171 m above sea level. 18 km away: Lysyanka, the nearest bigger centre, the same 1,148. Snow and wind from the nearest regional centre in the DBN — Черкаси, 78 km. 11.52 m between rows, pitch 15.34 m (latitude 49.4°).
- Yield of 1 kWp
- 1,143kWh/year
- Tilt
- 37°4° east of south
- 10 kW
- 11,431kWh/year
- Row pitch
- 15.34m · GCR 0.31
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,520 / 420Pa
Ground frame designer
A ground frame for a solar plant: Skrypchyntsi
The designer opens with this place’s coordinates, latitude 49.4° for the row spacing and the DBN loads of the nearest regional centre — Черкаси, 78 km: snow 1,520 Pa, wind 420 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 146 kWh/kWp, December: 27 — 5.4 times less.
February: 57 against 55 in the oblast, 3.6% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,716 | 730 | 135 |
| 10 | 11,431 | 1,460 | 270 |
| 15 | 17,147 | 2,190 | 405 |
Example: a 10 kW ground frame
For the loads of Cherkasy: 11.16 kWp, 18 panels, 346 kg of steel, 12 piles, materials ≈ 51,820 UAH.
How these numbers are computed
Nearby
- Sklymentsi3 km1,139 kWh/kWp
- Sydorivka4 km1,148 kWh/kWp
- Shenderivka4 km1,145 kWh/kWp
- Khylky4 km1,143 kWh/kWp
- Huta-Steblivska5 km1,148 kWh/kWp
- Zarichchia6 km1,141 kWh/kWp
All places: Zvenyhorodskyi RaionCherkasy Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.