Solar plant: site data

Solar power plant in Myzynivka, Zvenyhorodskyi Raion, Cherkasy Oblast

Myzynivka: 1,150 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). 0.5% above the oblast median (1,144). #9 of 197 in the rayon, #180 of 731 in the oblast.

Shpola, the rayon centre, is 42 km away. 149 m above sea level. 10 km away: Zvenyhorodka, the nearest bigger centre, the same 1,145. Snow and wind from the nearest regional centre in the DBN — Черкаси, 95 km. 11.05 m between rows, pitch 14.92 m (latitude 49.1°).

Yield of 1 kWp
1,150kWh/year
Tilt
36°4° east of south
10 kW
11,500kWh/year
Row pitch
14.92m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,520 / 420Pa

Ground frame designer

A ground frame for a solar plant: Myzynivka

The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Черкаси, 95 km: snow 1,520 Pa, wind 420 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan56Feb94Mar119Apr139May143Jun148Jul144Aug117Sep88Oct40Nov28Dec

July: 148 kWh/kWp, December: 28 — 5.3 times less.

November: 40 against 39 in the oblast, 2.6% more.

Myzynivka: plants, kWh
kWpA yearJulyDecember
55,750740140
1011,5001,480280
1517,2502,220420

Snow and wind: Черкаси

Example: a 10 kW ground frame

For the loads of Cherkasy: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zvenyhorodskyi RaionCherkasy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.