Section of the table from the Solispec engine (median zone — Cherkasy)

GCL

Ground frame for 20 GCL-NT10R/54GDF 440 panels (2×10)

2 rows of 10 panels, 8.80 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
8.80kW
Steel
343.3kg
Posts
12
Bolts
130
Materials
43,163₴
Yield
10,021kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the GCL-NT10R/54GDF 440 panel and the 2 × 10 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsTube 60×60×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 60×40×2Tube 60×60×2Tube 60×60×2
Purlins and bracesC-channel 60×40×2C-channel 60×40×2C-channel 60×40×2
Frames5 frames, pitch up to 2,710 mm6 frames, pitch up to 2,200 mm6 frames, pitch up to 2,200 mm
Posts101212
Footings (bored concrete)10 pcs, Ø400 mm, depth 1,100 mm12 pcs, Ø300 mm, depth 1,100 mm12 pcs, Ø300 mm, depth 1,300 mm
Concrete1.52 m³1.03 m³1.21 m³
Tilt30°30°30°
Panel bottom / post top600 / 1,838 mm600 / 1,838 mm600 / 1,838 mm
Panel field size11,660 × 2,324 mm11,660 × 2,324 mm11,660 × 2,324 mm
Row spacing between tables (no shade on 21 December)7,950 mm at noon · 8,940 mm ±2 h8,810 mm at noon · 10,180 mm ±2 h9,660 mm at noon · 11,480 mm ±2 h
Steel300.6 kg343.3 kg351.9 kg
BoltsM10 — 76, M8 — 44M10 — 86, M8 — 44M10 — 86, M8 — 44
Panel clampsend 8, middle 36end 8, middle 36end 8, middle 36
Materials42,270 UAH43,163 UAH44,099 UAH
With installation and delivery65,440 UAH66,615 UAH67,551 UAH
Per 1 kW7,436 UAH/kW7,570 UAH/kW7,676 UAH/kW
Yield1,266 kWh/kW · 11,145 kWh/year1,139 kWh/kW · 10,021 kWh/year1,043 kWh/kW · 9,180 kWh/year
Strength σ/fy87%79%85%
Deflection / (L/200)92%68%73%
Rafter strength70%51%55%
Post utilisation14%16%17%
Utilisation92%92%76%
Depth vs frost depthokokok
Checks overallwith a cautionwith a cautionwith a caution

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Kherson: Frame spacing 2 710 mm, 5 frames. Purlin C-channel 60×40×2: strength 87%, deflection 92% of L/200 (snow on panel 489 Pa).Chernihiv: Frame spacing 2 200 mm, 6 frames. Purlin C-channel 60×40×2: strength 85%, deflection 73% of L/200 (snow on panel 1 106 Pa).
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Kherson: Foundation Ø400 × 1 100: 0.138 m³ of concrete per post. Wind uplift on the front post ≈ 12.3 kN (with γ=1.5) vs ≈ 13.4 kN (concrete weight + soil friction, estimate) → 92%.Cherkasy: Foundation Ø300 × 1 100: 0.078 m³ of concrete per post. Wind uplift on the front post ≈ 8.7 kN (with γ=1.5) vs ≈ 9.5 kN (concrete weight + soil friction, estimate) → 92%.

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,1036
П2Rear postTube 60×60×22,9636
Кр1Rafter (inclined beam)Tube 60×60×22,9646
Пк1Frame strutC-channel 60×40×21,4276
Х1Longitudinal brace (cross)C-channel 60×40×22,5274
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×25,6602
Р4Purlin (rail)C-channel 60×40×25,6602
—Bolt M10×140 / M10×80 set · frame and struts / purlins, braces, connectors——72
—Bolt M10×150 set · brace to post, strut to rafter — through spacer inserts——14
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——36
—Bolt M8×50 + channel nut——44
—Concrete for 12 posts, Ø300×1100——1.03 m³

Profile cutting

21 bars of 6,000 mm, 113.5 m of profile in total.

  • Tube 60×60×29 bars
  • C-channel 60×40×212 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
43,163₴
With installation and delivery
66,615₴
Per 1 kW
7,570UAH/kW

Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

All 20 lines of the engine's estimate, with prices
ItemQuantityPrice, UAHSum, UAH
Tube 60×60×2, stock length 6 000 mm9 bar21011,340
C-channel 60×40×2, stock length 6 000 mm12 bar23016,560
C-channel connector (splice plate L 300)4 pcs90360
Bolt M10×140 cl. 8.8 set — frame, struts30 pcs22660
Bolt M10×80 cl. 8.8 set — purlins, braces, connectors51 pcs221,122
Bolt M10×150 cl. 8.8 set — strut to rafter, brace to post — through spacer inserts14 pcs27378
End clamp 30 mm8 pcs35280
Mid clamp (30–40 mm)36 pcs321,152
Bolt M8×50 A2 + spring channel nut M849 pcs14686
Post base anchor pin (M10 / rebar Ø12)12 pcs20240
Borehole casing (roofing felt / PVC, 300 mm)12 pcs60720
Crushed stone 20–40 for the bottom of the boreholes0.08 m³90072
Earth electrode: 2 rods Ø16×1.5 m + strip 40×41 set1,5001,500
Wire PV-3 6 mm² green-yellow29 m351,015
Module earthing clip (under the clamp)20 pcs20400
Cable clip, stainless60 pcs5300
Zinc paint / cold galvanising spray 400 ml2 pcs350700
Concrete M200 for posts1.03 m³3,8003,914
Rebar Ø10 (4 bars per post)63 m281,764
Spacer inserts / packs — pieces of the same profile (from offcuts): 4 × 71 mm, 6 × 70 mm, 4 × 30 mm, 6 × 10 mm20 pcs00
Materials43,163

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 10,021 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel

The 2×10 layout with other panels

Next