A 50 kW ground-mounted solar plant in Mykolaiv: structure, materials, cost

84 Ulica UL-620M-132DDGN (dual glass bifacial) panels (52.08 kW) on 3 tables of 2 × 14. Snow and wind per the DBN for Mykolaiv: S₀ 870 Pa, W₀ 470 Pa.

Power
52.08kW
Steel
1,798.7kg
Posts
72
Bolts
666
Materials
242,733₴
Yield
65,007kWh/year

Ground frame designer

Design the 50 kW plant in the builder

Opens the 2 × 14 table with the Ulica UL-620M-132DDGN (dual glass bifacial) panel and the loads for Mykolaiv.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Panel

Ulica UL-620M-132DDGN (dual glass bifacial): 620 W, 2,382 × 1,134 mm, portrait.

One table's structure (tables: 3)

Layout3 tables, each 2 × 14 = 28 panels
Loads (DBN V.1.2-2:2006)snow S₀ 870 Pa, wind W₀ 470 Pa, frost depth 0.6 m
PostsTube 60×60×2
RaftersC-channel 60×40×2
Purlins and bracesC-channel 60×40×2
Frames12 frames, pitch up to 1,440 mm
Posts24
Footings (bored concrete)24 pcs, Ø400 mm, depth 900 mm
Concrete2.99 m³
Tilt30°
Panel bottom / post top600 / 2,287 mm
Panel field size16,276 × 3,102 mm
Row spacing between tables (no shade on 21 December)10,880 mm at noon · 12,270 mm ±2 h
Steel599.6 kg
BoltsM10 — 162, M8 — 60
Panel clampsend 8, middle 52
Materials80,911 UAH
With installation and delivery125,108 UAH
Per 1 kW7,207 UAH/kW
Yield1,248 kWh/kW · 21,669 kWh/year

Checks and cautions

CheckValueStatus
Strength σ/fy36%passes
Deflection / (L/200)20%passes
Rafter strength71%passes
Post utilisation14%passes
Utilisation85%with a caution
Depth vs frost depthokpasses
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Foundation Ø400 × 900: 0.113 m³ of concrete per post. Wind uplift on the front post ≈ 9.3 kN (with γ=1.5) vs ≈ 10.9 kN (concrete weight + soil friction, estimate) → 85%.

Bill of materials

The bill of materials and the estimate are per table; tables: 3.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,07412
П2Rear postTube 60×60×23,21212
Кр1Rafter (inclined beam)C-channel 60×40×23,92412
Пк1Frame strutC-channel 60×40×21,81812
Х1Longitudinal brace (cross)C-channel 60×40×22,1934
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×26,0002
Р4Purlin (rail)C-channel 60×40×26,0002
Р5Purlin (rail)C-channel 60×40×24,2762
Р6Purlin (rail)C-channel 60×40×24,2762
—Bolt M10×25 set · purlins, braces, connectors——34
—Bolt M10×80 set · purlin to rafter——48
—Bolt M10×90 set · strut to post — through spacer inserts——12
—Bolt M10×130 set · post–rafter — through spacer inserts——48
—Bolt M10×140 set · strut to rafter — through spacer inserts——12
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——52
—Bolt M8×50 + channel nut——60
—Concrete for 24 posts, Ø400×900——2.99 m³

Profile cutting

38 bars of 6,000 mm, 206.2 m of profile in total.

  • Tube 60×60×212 bars
  • C-channel 60×40×226 bars

Estimated cost

The bill of materials and the estimate are per table; tables: 3.

Materials per table
80,911₴
With installation and delivery
125,108₴
Per 1 kW
7,207UAH/kW

The engine's estimate has 23 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Materials for all tables (3): 242,733 UAH.

Yield

Yield: 1,248 kWh per 1 kW a year, ≈ 65,007 kWh a year in total for Mykolaiv (tilt 30°, the optimum for the latitude is 34.4°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other sizes in Mykolaiv

50 kW in other regional centres