Section of the table from the Solispec engine (Mykolaiv)

Ground plant · Mykolaiv

A 12 kW ground-mounted solar plant in Mykolaiv: structure, materials, cost

20 Ulica UL-620M-132DDGN (dual glass bifacial) panels (12.40 kW) on 1 table of 2 × 10. Snow and wind per the DBN for Mykolaiv: S₀ 870 Pa, W₀ 470 Pa.

Power
12.40kW
Steel
416.9kg
Posts
16
Bolts
150
Materials
55,532₴
Yield
15,478kWh/year

Ground frame designer

Design the 12 kW plant in the builder

Opens the 2 × 10 table with the Ulica UL-620M-132DDGN (dual glass bifacial) panel and the loads for Mykolaiv.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Panel

Ulica UL-620M-132DDGN (dual glass bifacial): 620 W, 2,382 × 1,134 mm, portrait.

The table's structure

Layout1 table, each 2 × 10 = 20 panels
Loads (DBN V.1.2-2:2006)snow S₀ 870 Pa, wind W₀ 470 Pa, frost depth 0.6 m
PostsTube 60×60×2
RaftersC-channel 60×40×2
Purlins and bracesC-channel 60×40×2
Frames8 frames, pitch up to 1,600 mm
Posts16
Footings (bored concrete)16 pcs, Ø400 mm, depth 900 mm
Concrete1.99 m³
Tilt30°
Panel bottom / post top600 / 2,287 mm
Panel field size11,660 × 3,102 mm
Row spacing between tables (no shade on 21 December)10,880 mm at noon · 12,270 mm ±2 h
Steel416.9 kg
BoltsM10 — 106, M8 — 44
Panel clampsend 8, middle 36
Materials55,532 UAH
With installation and delivery87,537 UAH
Per 1 kW7,059 UAH/kW
Yield1,248 kWh/kW · 15,478 kWh/year

Checks and cautions

CheckValueStatus
Strength σ/fy44%passes
Deflection / (L/200)28%passes
Rafter strength79%passes
Post utilisation15%passes
Utilisation95%with a caution
Depth vs frost depthokpasses
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Foundation Ø400 × 900: 0.113 m³ of concrete per post. Wind uplift on the front post ≈ 10.4 kN (with γ=1.5) vs ≈ 10.9 kN (concrete weight + soil friction, estimate) → 95%.

Bill of materials

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,0748
П2Rear postTube 60×60×23,2128
Кр1Rafter (inclined beam)C-channel 60×40×23,9248
Пк1Frame strutC-channel 60×40×21,8188
Х1Longitudinal brace (cross)C-channel 60×40×22,3044
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×25,6602
Р4Purlin (rail)C-channel 60×40×25,6602
—Bolt M10×25 set · purlins, braces, connectors——18
—Bolt M10×80 set · purlin to rafter——32
—Bolt M10×90 set · strut to post — through spacer inserts——8
—Bolt M10×130 set · post–rafter — through spacer inserts——32
—Bolt M10×140 set · strut to rafter — through spacer inserts——8
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——36
—Bolt M8×50 + channel nut——44
—Concrete for 16 posts, Ø400×900——1.99 m³

Profile cutting

26 bars of 6,000 mm, 144.1 m of profile in total.

  • Tube 60×60×28 bars
  • C-channel 60×40×218 bars

Estimated cost

Materials
55,532₴
With installation and delivery
87,537₴
Per 1 kW
7,059UAH/kW

The engine's estimate has 23 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,248 kWh per 1 kW a year, ≈ 15,478 kWh a year in total for Mykolaiv (tilt 30°, the optimum for the latitude is 34.4°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other sizes in Mykolaiv

12 kW in other regional centres

Next