Section of the table from the Solispec engine (Lviv)

Ground plant · Lviv

A 50 kW ground-mounted solar plant in Lviv: structure, materials, cost

84 Ulica UL-620M-132DDGN (dual glass bifacial) panels (52.08 kW) on 3 tables of 2 × 14. Snow and wind per the DBN for Lviv: S₀ 1,310 Pa, W₀ 520 Pa.

Power
52.08kW
Steel
1,550.3kg
Posts
54
Bolts
576
Materials
229,851₴
Yield
58,359kWh/year

Ground frame designer

Design the 50 kW plant in the builder

Opens the 2 × 14 table with the Ulica UL-620M-132DDGN (dual glass bifacial) panel and the loads for Lviv.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Panel

Ulica UL-620M-132DDGN (dual glass bifacial): 620 W, 2,382 × 1,134 mm, portrait.

One table's structure (tables: 3)

Layout3 tables, each 2 × 14 = 28 panels
Loads (DBN V.1.2-2:2006)snow S₀ 1,310 Pa, wind W₀ 520 Pa, frost depth 0.9 m
PostsTube 60×60×2
RaftersC-channel 80×40×2
Purlins and bracesC-channel 60×40×2
Frames9 frames, pitch up to 1,960 mm
Posts18
Footings (bored concrete)18 pcs, Ø400 mm, depth 1,200 mm
Concrete2.99 m³
Tilt30°
Panel bottom / post top600 / 2,278 mm
Panel field size16,276 × 3,107 mm
Row spacing between tables (no shade on 21 December)12,090 mm at noon · 14,030 mm ±2 h
Steel516.8 kg
BoltsM10 — 132, M8 — 60
Panel clampsend 8, middle 52
Materials76,617 UAH
With installation and delivery120,957 UAH
Per 1 kW6,968 UAH/kW
Yield1,121 kWh/kW · 19,453 kWh/year

Checks and cautions

CheckValueStatus
Strength σ/fy85%with a caution
Deflection / (L/200)66%passes
Rafter strength84%with a caution
Post utilisation24%passes
Utilisation96%with a caution
Depth vs frost depthokpasses
  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Frame spacing 1 960 mm, 9 frames. Purlin C-channel 60×40×2: strength 85%, deflection 66% of L/200 (snow on panel 842 Pa).
  • Rafter profileThe rafter is used above 80 %, or the frame's posts stand far apart: the structure passes, but the margin is small.Rafter C-channel 80×40×2: span between posts 2 276, cantilever 824 mm → strength 84%.
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Foundation Ø400 × 1 200: 0.151 m³ of concrete per post. Wind uplift on the front post ≈ 14.0 kN (with γ=1.5) vs ≈ 14.6 kN (concrete weight + soil friction, estimate) → 96%.

Bill of materials

The bill of materials and the estimate are per table; tables: 3.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,3659
П2Rear postTube 60×60×23,5039
Кр1Rafter (inclined beam)C-channel 80×40×23,9249
Пк1Frame strutC-channel 60×40×21,8119
Х1Longitudinal brace (cross)C-channel 60×40×22,5674
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×26,0002
Р4Purlin (rail)C-channel 60×40×26,0002
Р5Purlin (rail)C-channel 60×40×24,2762
Р6Purlin (rail)C-channel 60×40×24,2762
—Bolt M10×25 set · purlins, braces, connectors——34
—Bolt M10×90 set · strut to post — through spacer inserts——9
—Bolt M10×100 set · purlin to rafter——36
—Bolt M10×130 set · post–rafter — through spacer inserts——36
—Bolt M10×140 set · strut to rafter — through spacer inserts——9
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——52
—Bolt M8×50 + channel nut——60
—Concrete for 18 posts, Ø400×1200——2.99 m³

Profile cutting

35 bars of 6,000 mm, 179.8 m of profile in total.

  • Tube 60×60×29 bars
  • C-channel 80×40×29 bars
  • C-channel 60×40×217 bars

Estimated cost

The bill of materials and the estimate are per table; tables: 3.

Materials per table
76,617₴
With installation and delivery
120,957₴
Per 1 kW
6,968UAH/kW

The engine's estimate has 24 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Materials for all tables (3): 229,851 UAH.

Yield

Yield: 1,121 kWh per 1 kW a year, ≈ 58,359 kWh a year in total for Lviv (tilt 30°, the optimum for the latitude is 35.4°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other sizes in Lviv

50 kW in other regional centres

Next