1 1342 27830
Drawn to scale from the datasheet dimensions, mm

GCL

GCL-NT10/72GDF 590

GCL-NT10/72GDF 590 — solar panel: 590 W, 2,278×1,134×30 mm, 31.1 kg, Voc 52.2 V, Isc 14.13 A. On the Deye SUN-3.6K-SG03LP1-EU at −20 °C a string takes 4–8 modules. One module covers 2.58 m², that is 4.4 m² per kWp.

Power
590W
Voc
52.2V
Isc
14.13A
Weight
31.1kg
  • bifacial

Ground frame designer

A ground frame for GCL-NT10/72GDF 590

The designer opens with this panel: its size and weight are already in the profiles, posts and estimate.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Specifications

ManufacturerGCL
Power, W590
Dimensions, mm2278×1134×30
Weight, kg31.1
Cells144 (72) 182 мм
Voc, V52.2
Isc, A14.13
Vmp, V44.15
Imp, A13.37
Temp. coeff. Voc, %/°C-0.25
Bifacialyes

Data from manufacturer datasheets; check before purchase.

For the installer: space, weight and strings

Module area, m²2.58
Area per kWp, m²4.4
Weight per kWp, kg52.7
Module efficiency (STC), %22.8
For 10 kWp17 modules (10 kWp)

Modules per string: −20 °C and a +70 °C cell

InverterPer stringModule Voc at −20 °C, VStrings per MPPT inputMax per inverterCheck
Deye SUN-3.6K-SG03LP1-EU4–858.0717 pcs · 4.1 kWpCalculator
Growatt SPF 5000 ES4–758.0717 pcs · 4.1 kWpCalculator
Solis S6-EH1P6K-L-PLUS3–858.07116 pcs · 9.4 kWpCalculator

The Solispec engine computes the window: Voc at −20 °C sets the string maximum, Vmp at a +70 °C cell sets the MPPT minimum. Check both makers’ datasheets.

Snow and wind loads depend on the site. Calculate for your address

Datasheet

The specifications on this page come from this document; it opens on the maker’s site.

The maker’s documents

  • Installation manual GCL SI Installation Manual for GCL Solar PV Modules (AU edition, 2024-07) (EN)
  • Installation manual GCL SI Installation Manual (XXJC-2-RD-2144 C4, AU edition) (EN)
  • Warranty GCL SI Limited Warranty for PV Modules (EN)
  • Certificate TUV Rheinland IEC 61215 / IEC 61730 certificate, NT10-78GDF, NT10-72GDF, NT10-54GDF and NT (EN)
  • Certificate TUV Rheinland compliance document D 093675 0035 (IEC 61215 / 61730, IEC 62716 ammonia), NT (EN)
  • Certificate TUV Rheinland compliance document D 093675 0037 (IEC 61215 / 61730, IEC 61701 salt mist), (EN)
  • Certificate TUV Rheinland compliance document D 093675 0039 (IEC 61215 / 61730, IEC 60068-2-68 dust an (EN)

Manuals, certificates and the warranty — PDFs on the maker’s site; the document’s language in brackets.

GCL-NT10/72GDF 590 datasheet + a string calculation — by e-mail

One e-mail: the maker’s datasheet (PDF), the calculator with this model and the designer.

With the e-mail we reserve −20 % off Pro for this address — confirm it in a separate e-mail.

How we handle your data: privacy policy.

Similar models from other makers

Frequently asked questions

How many GCL-NT10/72GDF 590 modules fit in a string on the Deye SUN-3.6K-SG03LP1-EU?
At −20 °C from 4 to 8 modules: the upper limit comes from the cold Voc and the input’s maximum voltage, the lower one from the MPPT window with a +70 °C cell.
How much space and weight do GCL-NT10/72GDF 590 modules take per kWp?
4.4 m² and 52.7 kg per kWp (one module is 2.58 m²). A 10 kWp plant needs 17 modules.
What is the open-circuit voltage of the GCL-NT10/72GDF 590 in the cold?
The datasheet gives a Voc of 52.2 V at STC; at −20 °C the Solispec engine gives 58.07 V per module. The string length depends on that number.