Ground-mount frame for 30 kWp: loads and foundations

A 30 kWp ground-mount solar frame worked through for Kyiv and Krakow. Snow and wind, rails, rafters, posts, braces, member utilisation and the load each foundation must carry.

By Solispec editorial7 min read

A ground-mounted solar panel frame for 30 kWp is 52 modules of 580 W in two rows at 35 degrees: 16 frames 1970 mm apart on 32 posts. Everything passes in Kyiv and Krakow. The rail is the most loaded (72 % and 70 %); the footing takes 51 % and 63 %. Results are preliminary.

Below: the table, the loads of both sites with their clauses, the members and their utilisation, and the load each post hands to the ground. The figures come from the same engine that runs the ground mount calculator, in its ground table mode with concrete footings.

The table

  • Module: LONGi Hi-MO 6 LR5-72HTH-580M, 580 W, 2278 x 1134 mm. 52 modules make 30.16 kWp.
  • Layout: 2 rows of 26 modules in portrait, tilt 35 degrees (the engine's optimum for latitude 50 is about 35). The top edge is 3253 mm above the ground, the lower edge 600 mm.
  • Frames: 16 frames at a 1970 mm step, two posts each, so 32 posts. A row is 29984 mm long.
  • Members: rails (purlins) C 60 x 40 x 2, rafter C 100 x 50 x 2.5, posts tube 60 x 60 x 2.
  • Footing under each post: concrete, diameter 350 mm, depth 1300 mm, 0.125 m³ per post.

Loads at the two sites

Kyiv (Ukraine)Krakow (Poland)
Rule setDBN V.1.2-2:2006, amendments 1 and 2EN 1990, EN 1991-1-3, EN 1991-1-4 with the national annex values
Ground snow, PaS0 = 1550 (annex E)s_k = 1200
Wind, PaW0 = 370 (annex E)q_b = 300
Snow shape coefficient0.71 (annex Zh, scheme 1)0.67 (EN 1991-1-3, 5.2)
Design snow on the plan, Pa11071200
Wind factor at 3.3 mc_e(z) = 1.68 (EN 1991-1-4, 4.5, terrain II, in place of C_h = 0.70 of table 9.01)c_e(z) = 1.68 (EN 1991-1-4, 4.5, terrain II)
Design wind pressure, Pa623758
Force coefficient, lift / pressure2.00 / 1.35 (EN 1991-1-4, table 7.6, as DBN 9.8 allows)2.00 / 1.35 (the same table)
CombinationDBN 4.18, snow and wind each leadingEN 1990 (6.10), factor 1.5 on variable actions

Both pressures carry the same exposure factor c_e = 1.68. The force coefficients of EN 1991-1-4 table 7.6 are defined on the peak pressure, so in Ukraine the wind on them is Wm = γfm · W0 · c_e(z) · Calt = 1.00 · 370 · 1.68 = 623 Pa, with W0 (the mean 50-year pressure at 10 m, DBN 9.6) taken as q_b; DBN's own C_h = 0.70 of table 9.01 is a mean-wind height factor and goes with DBN's own coefficients only. The Krakow 758 Pa is 1.5 · 300 · 1.68: a lower q_b, but the EN factor 1.5 instead of the DBN factor 1.00 for a 50-year return period.

The frame

Each frame is a rafter on two posts, held by a knee brace. Rails run along the table on the rafters and carry the modules.

MemberSectionDimension
Rail (purlin)C 60 x 40 x 2span 1970 mm between frames
RafterC 100 x 50 x 2.5length 3756 mm, span between posts 2178 mm, overhang 789 mm
Front posttube 60 x 60 x 21197 mm above the ground, 2497 mm cut with 1300 mm in concrete
Rear posttube 60 x 60 x 22447 mm above the ground, 3747 mm cut with 1300 mm in concrete
Knee braceC 60 x 4016 pieces of 1808 mm, one per frame, rear post to the middle of the rafter
Cross brace between rear postsC 60 x 404 pieces of 2633 mm in the end bays

The posts stand at 0.21 of the rafter length from its ends, which makes the moment in the span and on the overhangs about equal.

Utilisation of the members

CheckKyivKrakow
Rail, strength (M / W / f_y)72 %70 %
Rail, deflection (against L/200)26 %43 %
Rafter, strength28 %27 %
Rear post, compression, N / N_b,Rd18 %17 %
Footing, uplift against holding force51 %63 %
Frost depth against embedment1.10 m against 1.30 m, ok1.00 m against 1.30 m, ok

The rail is the most loaded steel member at both sites, since it spans a full 1970 mm under the panel load. Rafter and post have a wide margin. The footing is the line that moves most between the sites. Frost depth is 1.10 m for the Kyiv region and 1.00 m for Krakow (zone II of the PN-81/B-03020 map the engine uses as a guide). Verify it against local data.

What each post hands to the ground

ReactionKyivKrakow
Uplift on the front post, kN6.908.40
Holding force of the Ø350 x 1300 footing, kN13.4213.42
Compression on the rear post, kN8.858.59
Post capacity, kN50.450.4

The uplift is 0.75 F_z, where F_z = γn · c_f · W_m · A · cos α is the vertical wind force on the frame (the report notes the factor 1.5). The holding force is 0.9 of the concrete weight plus the soil friction on the side surface, an estimate. The compression is about 0.6 of the frame load on the rear post.

The engine does not report a horizontal (shear) force on the post, the bearing pressure under the footing or a pull-out capacity measured on the site. These depend on the soil and belong to the engineer.

What it means for the foundation type

  • Concrete footing, as the engine checks it. Ø350 x 1300 mm holds 13.42 kN against 6.90 kN in Kyiv and 8.40 kN in Krakow. It passes at both sites and reaches below frost.
  • Driven or screw pile. The same uplift figures become the requirement: the pile must resist at least 6.90 kN (Kyiv) or 8.40 kN (Krakow) in pull-out, with the frost depth and the lateral load on top. The engine does not compute a pile capacity. It comes from a geotechnical report or a pull-out test on the plot.
  • Where wind rules. In Krakow the footing is used three times more than in Kyiv. A windier site raises this line first, because uplift grows with the wind pressure while the holding force of the footing stays the same.

Checklist before ordering steel

  1. Enter the site's own snow and wind (a city is a proposal, not your plot) and the terrain category.
  2. Check that no critical item is left in the report. Here there are none at both sites.
  3. Read the footing line: uplift against holding force, and the embedment against frost depth.
  4. For piles, ask for a soil report or a pull-out test and compare it with the uplift above.
  5. Check the lateral load and the bearing pressure, which the report does not give.
  6. Fix the frame step, tilt and row distance (shading) with the layout, not by the structure alone.
  7. Have a qualified engineer approve the result before installation.

A comparison of the engine with a hand calculation is on the calculation check page. A sample report with drawings and a cut list is on the samples page. For tilt, rows and the other ground options see ground mounting, and for your own snow and wind the snow and wind calculator. The full set comes from the designer.

The calculation is preliminary. Loads follow DBN V.1.2-2 for Ukraine and the national annex values with EN 1990 combinations for Poland. A qualified engineer must check it before installation.

FAQ

How many modules make a 30 kWp ground-mount system?

With 580 W modules, 52 of them: 30.16 kWp. Two rows of 26 modules in portrait gives a table about 30 m long.

Which part of a ground-mount frame governs?

The rail, at 72 % in Kyiv and 70 % in Krakow. The footing follows at 51 % and 63 % because wind uplift decides it.

Can I use screw piles instead of concrete?

Yes, if the pile resists the uplift above and the lateral load in your soil. The pile capacity comes from a geotechnical check, not from the frame calculation.

StructuresNorms

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate