Solar plant: site data

Solar power plant in Volytsia, Zhytomyrskyi Raion, Zhytomyr Oblast

Volytsia: 1,120 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 1.4% above the oblast median (1,104). #110 of 686 in the rayon, #116 of 1700 in the oblast.

Zhytomyr, the rayon centre, is 35 km away. 220 m above sea level. 35 km away: Zhytomyr, the nearest bigger centre, 1,108 — 1.1% more here. Snow and wind from the nearest regional centre in the DBN — Житомир, 35 km. 12.17 m between rows, pitch 15.99 m (latitude 50.1°).

Yield of 1 kWp
1,120kWh/year
Tilt
37°3° east of south
10 kW
11,199kWh/year
Row pitch
15.99m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,460 / 460Pa

Ground frame designer

A ground frame for a solar plant: Volytsia

The designer opens with this place’s coordinates, latitude 50.1° for the row spacing and the DBN loads of the nearest regional centre — Житомир, 35 km: snow 1,460 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

30Jan54Feb92Mar120Apr137May143Jun143Jul140Aug113Sep85Oct36Nov27Dec

June: 143 kWh/kWp, December: 27 — 5.3 times less.

January: 30 against 34 in the oblast, 11.8% less.

Volytsia: plants, kWh
kWpA yearJuneDecember
55,600715135
1011,1991,430270
1516,7992,145405

Snow and wind: Житомир

Example: a 10 kW ground frame

For the loads of Zhytomyr: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zhytomyrskyi RaionZhytomyr Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.