Solar plant: site data

Solar power plant in Portselianove, Zviahelskyi Raion, Zhytomyr Oblast

Portselianove: 1,097 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.7% below the oblast median (1,104). #173 of 294 in the rayon, #1222 of 1700 in the oblast.

Zvyahel, the rayon centre, is 44 km away. 226 m above sea level. 13 km away: Polonne, the nearest bigger centre, 1,103 — 0.5% less here. Snow and wind from the nearest regional centre in the DBN — Житомир, 73 km. 12.27 m between rows, pitch 16.09 m (latitude 50.2°).

Yield of 1 kWp
1,097kWh/year
Tilt
37°2° east of south
10 kW
10,969kWh/year
Row pitch
16.09m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,460 / 460Pa

Ground frame designer

A ground frame for a solar plant: Portselianove

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Житомир, 73 km: snow 1,460 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan55Feb91Mar117Apr132May137Jun138Jul135Aug110Sep82Oct36Nov29Dec

July: 138 kWh/kWp, December: 29 — 4.8 times less.

December: 29 against 27 in the oblast, 7.4% more.

Portselianove: plants, kWh
kWpA yearJulyDecember
55,485690145
1010,9691,380290
1516,4542,070435

Snow and wind: Житомир

Example: a 10 kW ground frame

For the loads of Zhytomyr: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zviahelskyi RaionZhytomyr Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.