Solar plant: site data
Solar power plant in Novi Saly, Zhytomyrskyi Raion, Zhytomyr Oblast
Novi Saly: 1,105 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). Exactly the oblast median (1,104). #508 of 686 in the rayon, #837 of 1700 in the oblast.
Zhytomyr, the rayon centre, is 45 km away. 188 m above sea level. 33 km away: Korosten, the nearest bigger centre, the same 1,105. Snow and wind from the nearest regional centre in the DBN — Житомир, 47 km. 13.03 m between rows, pitch 16.80 m (latitude 50.7°).
- Yield of 1 kWp
- 1,105kWh/year
- Tilt
- 38°2° east of south
- 10 kW
- 11,046kWh/year
- Row pitch
- 16.80m · GCR 0.28
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,460 / 460Pa
Ground frame designer
A ground frame for a solar plant: Novi Saly
The designer opens with this place’s coordinates, latitude 50.7° for the row spacing and the DBN loads of the nearest regional centre — Житомир, 47 km: snow 1,460 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 141 kWh/kWp, December: 27 — 5.2 times less.
January: 35 against 34 in the oblast, 2.9% more.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,523 | 705 | 135 |
| 10 | 11,046 | 1,410 | 270 |
| 15 | 16,569 | 2,115 | 405 |
Example: a 10 kW ground frame
For the loads of Zhytomyr: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.
How these numbers are computed
Nearby
- Rosivka2 km1,104 kWh/kWp
- Osivka3 km1,104 kWh/kWp
- Saly4 km1,110 kWh/kWp
- Yemylivka4 km1,107 kWh/kWp
- Dobryn5 km1,099 kWh/kWp
- Huta-Dobryn5 km1,099 kWh/kWp
All places: Zhytomyrskyi RaionZhytomyr Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.