Solar power plant in Bycheva, Zhytomyrskyi Raion, Zhytomyr Oblast

Bycheva: 1,101 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). Exactly the oblast median (1,104). #570 of 686 in the rayon, #1039 of 1700 in the oblast.

Zhytomyr, the rayon centre, is 86 km away. 278 m above sea level. 21 km away: Stara Synyava, the nearest bigger centre, 1,109 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 68 km. 11.58 m between rows, pitch 15.45 m (latitude 49.8°).

Yield of 1 kWp
1,101kWh/year
Tilt
36°2° east of south
10 kW
11,005kWh/year
Row pitch
15.45m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Bycheva

The designer opens with this place’s coordinates, latitude 49.8° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 68 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

30Jan50Feb84Mar118Apr135May139Jun143Jul138Aug112Sep84Oct37Nov29Dec

July: 143 kWh/kWp, December: 29 — 4.9 times less.

January: 30 against 34 in the oblast, 11.8% less.

Bycheva: plants, kWh
kWpA yearJulyDecember
55,503715145
1011,0051,430290
1516,5082,145435

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zhytomyrskyi RaionZhytomyr Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.